Code: QX136512

Acid-Inert Hotplate A2 (60x40cm)

Previous QMX Code: PL-A2-2V

Acid Inert Hotplates are ideal for any digestion, concentration or common heating method that requires a temperature up to 240°C*.

A2 model: 600 x 400mm

Includes PTFE bench and side thermal protection for user safety and protection of surfaces from radiated heat.

Requires a separate controller for operation. Please select from a simple non-programmable controller or a programmable controller for advanced operation. Controllers also available with external probes for control and monitoring of sample temperature.

*For the A2 model only, maximum temperature of 240°C when using a 16A power supply and 165°C when using a standard 13A power supply. Please specify your power requirement on request. 

Unit Size: 1

Acid Inert Hotplates are made from pure graphite with a PFA coating allowing rapid heat distribution across the whole block whilst delivering acid resistance to ensure a reliable, long lasting product even in the most corrosive environment.

Ideal for any digestion, concentration or common heating method that requires a temperature up to 240°C*. An A4 hotplate achieves a constant temperature of 150°C within 8 minutes.

The hotplates are available in 3 standard sizes but can be tailor-made to meet your application. They can be used as common hotplates and for sample digestions in a multitude of vessels simply by adding a rack.

A2 model: 600 x 400mm

  • Manufactured from graphite providing excellent heating uniformity across the entire surface with no hot spots
  • Coated with acid resistant PFA to provide excellent corrosion protection
  • PTFE bench and side protection included for user safety and protection of surfaces from radiated heat
  • Can be tailored to your specification to optimise your working space
  • Available with a range of controllers to suit budget and application
  • Additional graphite PFA coated racks can be tailored to your laboratory’s unique needs 
  • Also with a side Rim to aid securing racks and enhance performance

Note: A separate controller is required to operate the hotplate and is available in 2 base configurations. Please select from a simple non-programmable controller (without or with timer function) or a programmable controller for advanced operation. Controllers also available with external probes for control and monitoring of sample temperature.

*For the A2 model only, 240°C maximum temperature is achievable when the controller is connected to a 16A power supply using an appropriate power cable otherwise when using a standard 13A power supply and cable the maximum temperature achievable is 165°C. Please specify your power requirement on request. 

Please contact us for advice on choosing the right product for your application.

Family
  • Analab
Plate Size
  • A2
Product Type
  • Hotplate
Related Products